    Load cell for tensile and compression from 1000 KN to 2000KN

    Load cell for tensile and compression from 1000 KN to 2000KN

    Key Benefits
    • through holes for mounting bolts simplify installation and allow a wide range of testing situations to be accommodated
    • hermetically sealed, corrosion-resistant design for high long-term reliability

    More detail

    Categories: ,
    • Description
    • Reviews (0)
    • Technical Data

    Product Description

    Further advantages und features
    • Rotational symmetrical measurement body (computer optimised), thus measurement properties are independent of the mounting location
    • Independent of the stiffness (and so deflection) of the force transmission
    • Insensitive to eccentric force transmission and lateral forces
    • No influence through torsional moments
    • Low creep error even at abrupt load removal (specimen break)
    • The inside of the extensometer is filled with protective gas, so no reaction with oxygen (from air or moisture) is possible
    • All hollows are laser welded, and so a long-time stable and very high consistency will be reached towards the environment
    • In fatigue tests controlled firmness means quasiunlimited life of the materials testing machine
    • High static overloading gives more protection to the user (tensile strength 300% nominal force)

    Reviews

    There are no reviews yet.


    Be the first to review “Load cell for tensile and compression from 1000 KN to 2000KN”

    Technical data

    Fmax (tensile/compression) [kN]1 1000 1200 1500 1600 2000
    Accuracy grade 1 from ... on [kN] 2.0 2.4 3.0 3.2 4.0
    Accuracy grade 0.5 from ... on [kN] 10.0 12.0 15.0 16.0 20.0
    Nominal measurement path [mm] 0.41 0.49 0.40 0.40 0.39
    Dimensions          
    H – Height [mm] 326 326 326 326 326
    D1 – Upper mounting stud diameter [mm] 305 305 305 305 305
    d1 – Upper mounting stud diameter [mm] 250 250 250 250 250
    D2 – Lower mounting stud diameter [mm] 305 305 305 305 305
    d2 – Lower mounting stud diameter [mm] 250 250 250 250 250
    Eccentricity influence / mm 0.02 % 0.02 % 0.02 % 0.02 % 0.02 %
    Lateral force influence at 0.1 x Fnom          
    on the load cell upper side 0.02 % 0.02 % 0.02 % 0.02 % 0.02 %
    Reference temperature [°C] 22 (±1) 22 (±1) 22 (±1) 22 (±1) 22 (±1)
    Nominal temperature range [°C] +10 ... +60 +10 ... +60 +10 ... +60 +10 ... +60 +10 ... +60
    Use temperature range [°C] -30 ... +85 -30 ... +85 -30 ... +85 -30 ... +85 -30 ... +85
    Storage temperature range [°C] -50 ... +85 -50 ... +85 -50 ... +85 -50 ... +85 -50 ... +85
    Limit force 150 % 150 % 150 % 150 % 150 %
    Static limit lateral force 100 % 100 % 100 % 100 % 100 %
    Tensile force 300 % 300 % 300 % 300 % 300 %
    Protection system to DIN 40050 part 1 IP67 IP67 IP67 IP67 IP67
    Item no. 358456 358457 630382 643070 011275